2 - 67
2 SYSTEM CONFIGURATION
Correspondence between dno.s and axis select switches of servo amplifier
dno.
(Note)
SSCNET
system
Axis select switch
of servo amplifier
dno.
(Note)
SSCNET
system
Axis select switch
of servo amplifier
d01 1 "0" d01 2 "0"
d02 1 "1" d02 2 "1"
d03 1 "2" d03 2 "2"
d04 1 "3" d04 2 "3"
d05 1 "4" d05 2 "4"
d06 1 "5" d06 2 "5"
d07 1 "6" d07 2 "6"
d08 1 "7"
d08 2 "7"
d09 1 "8" d09 2 "8"
d10 1 "9" d10 2 "9"
d11 1 "A" d11 2 "A"
d12 1 "B" d12 2 "B"
d13 1 "C" d13 2 "C"
d14 1 "D" d14 2 "D"
d15 1 "E" d15 2 "E"
d16 1 "F" d16 2 "F"
(Note) : The dno. is number of servo amplifier axis displayed with SSCNET structure screen of
MT Developer.
Axis No. is set relative to dno. in the SSCNET structure screen of system settings.
Correspondence between SSCNET system and connector No. of CPU module
is shown below.
Correspondence between SSCNET system No. and connector No. of CPU module
SSCNET system No. Connector No. of CPU
1 SSCNET CN1
2 SSCNET CN2
(Note) : Number of SSCNET systems: Q173DCPU : 2 systems / Q172DCPU : 1 system