18 XSEL
Teaching Pendant
ANSI standard/CE mark compliant teaching pendant (for use with General purpose type only)
Model
Model
Dimensional
Drawing
Dimensional
Drawing
Features
Features
• A teaching device offering program/position input function, test operation function, monitoring
function, and more.
• Interactive operation enables anyone to use this device easily.
• Has Deadman switch specification with improved safety performance.
IA-T-X
(standard)
IA-T-XD
(equipped with Deadman switch)
Specification
Specification
Item Specifications
Ambient operating
temperature and humidity
Ambient operating environment
Weight
Cable length
Display
Temperature 0 to 40°C, Humidity 85%RH or less
Free from corrosive gases. In particular, there shall be no significant
amount of dust.
Approx. 650g
4m
20 character × 4 row LCD display
* Versions earlier than Ver. 1.13
cannot be used for XSEL-P/Q.
* Versions earlier than Ver. 1.08
cannot be used for SCARA.
45
28
90
265
120
Splash-proof type that complies with IP54 protection class. Usability has been enhanced with
dedicated keys set for each function. SEL-TD/SEL-TG are also equipped with a 3-position
enable switch and support ANSI standards.
SEL-T
SEL-TD
(ANSI-compliant)
SEL-TG
(Safety category compatible)
Teaching Pendant – Controller Compatibility Chart
SEL-TG wiring diagram
Item
Item
Specifications
Temperature 0 to 40 °C, Humidity 30 to 85% RH or less (non- condensing)
IP54 (not including the cable connector part)
400g or less (not including the cable)
5m
32 character × 8 row LCD display
CE mark, ANSI standards (*)
218.3
39.0
46.9
89.6
(*) ANSI standards support SEL-TD/SEL-TG only.
IA-T-X
Standard type
IA-T-XD
Equipped with Deadman switch
SEL-T
Standard type
SEL-TD
Safety category compatible type
SEL-TG
Safety category compatible type
Program
Controller
PSEL/ASEL/SSEL
XSEL-J
XSEL-K
XSEL-P
XSEL-Q
XSEL-KT
XSEL-KE
XSEL-JX
XSEL-KX
XSEL-PX
XSEL-QX
○ (Note 1)
○
○
○
○
○
○
○
○
○
○
○ (Note 1)
○
○
○
○
○
○
○
○
○
○
○ (Note 1)
×
○
○
○
○
○
×
○
○
○
○ (Note 1)
×
○
○
◎
◎
○
×
○
○
◎
◎
○ (Note 2)
○
◎
◎
◎
○
○ (Note 2)
○
◎
◎
*◎ complies with safety categories B to 4,
○ indicates that non-compliance with the safety category, but that connection is possible.
Note 1: A conversion cable is also needed when connecting to PSEL/ASEL/SSEL.
Note 2: If connecting SEL-TG to the XSEL-J/JX controller, DC24V must be supplied to the TP adapter.
IA-LB-TG
5m
CB-SEL26H-LB005
0.5m
CB-SEL25-LB005
0.5m
ASELPSEL SSEL
SEL-TG
DC24V
( )
All XSEL models
For PSEL/ASEL/SSEL
Controller Connection Cable
Controller Connection Cable
TP adapter for SEL-TG
For XSEL
Controller
When using
XSEL-J
Safety
circuit
Ambient operating
temperature and humidity
Ambient operating environment
Weight
Cable length
Display
Safety Rating