Mitsubishi MOTION CONTROLLERS Q172DCPU Manuál s instrukcemi Strana 93

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 448
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 92
3 - 58
3 POSITIONING DEDICATED SIGNALS
(7) Manual pulse generator axis setting error flag (SM513)
.………...... Status signal
(a) This flag is use as judgement of normal or abnormal setting of the manual
pulse generator axis No. setting registers (D714 to D719).
• OFF ......... D714 to D719 is normal
• ON ......... D714 to D719 is abnormal
(b) When SM513 turns on, the error contents are stored in the manual pulse
generator axis setting error information (SD513 to SD515).
(8) Servo program setting error flag (SM516) ...........…... Status signal
This flag is used as judgement of normal or abnormal for the servo program
positioning data.
• OFF ...... Normal
• ON ...... Abnormal
Zobrazit stránku 92
1 2 ... 88 89 90 91 92 93 94 95 96 97 98 ... 447 448

Komentáře k této Příručce

Žádné komentáře