4. eWON Serial Configuration
For simple serial communication, you need only
- to select the eWON port (COM1 for the serial port)
- to set the Port Type to “Raw TCP” (let the TCP port to its default value, 23)
- to configure the Line Parameters (BaudRate, Data, Parity, Stop bit and HW mode) to
match the serial port of your device.
In the above configuration, the device used is a Twido configured in RS485, then the
HW Mode is set to Half-Duplex and the Dipswitch is on RS485.
eVCOM (Standard serial communications) Page 9/29
IMPORTANT
The VCOM must be the only process using the Serial Port!
Then, you must disable all eWON IOServers using this serial port.
Zobrazit stránku 8