CITY MULTI
MEE08K108
MITSUBISHI ELECTRIC MULTIPLE SPLIT TYPE AIR CONDITIONERS Series
The Air Conditioning & Refrigeration Systems Works acquired ISO 9001 certification under Series
9000 of the International Standard Organization (ISO) based on a review of Quality management for
the production of refrigeration and air conditioning equipment.
ISO Authorization System
The ISO 9000 series is a plant authorization system relating to quality management as stipulated by
the ISO. ISO 9001 certifies quality management based on the "design, development, production,
installation and auxiliary services" for products built at an authorized plant.
The Air Conditioning & Refrigeration Systems Works acquired environmental management system
standard ISO 14001 certification.
The ISO 14000 series is a set of standards applying to environmental protection set by the
International Standard Organization (ISO).
New publication effective May 2009
Specifications subject to change without notice
http://Global.MitsubishiElectric.com
FM33568 / ISO 9001;2000
AIR CONDITIONING SYSTEMS
CM09WD-F
Zobrazit stránku 0
1 2 3 4 5 6 ... 68 69

Shrnutí obsahu

Strany 1 - CM09WD-F

CITY MULTIMEE08K108MITSUBISHI ELECTRIC MULTIPLE SPLIT TYPE AIR CONDITIONERS SeriesThe Air Conditioning & Refrigeration Systems Works ac

Strany 2 - Our Latest Technologies

The need for control is paramount in order to optimise the performance of any air conditioning system and minimize its running costs. Mitsubishi Elect

Strany 3 - VRF system

Integrated Communications Control with Mitsubishi's Unique Transmission Network (M-NET)Page20Remote ControllerSystem ControllerMELANSUse of our M

Strany 4 - I nverter Driven Compressor

New display-Larger,easier-to-see charactersDot liquid crystal display● Display example [Operation mode]● Display example [Cool mode]ON/OFF TEMP. ˚F

Strany 5 - Total Energy Conservation

PAR-FL32MA PAR-FA32MA PAR-SA9FA(4-way Cassette signal receiver)Wireless remote controller PAR-FL32MA / PAR-FA32MAExample of system configurationCorres

Strany 6 - Efficient R410A refrigerant

System exampleR / C : Remote ControllerSystemremotecontrollerSchedule timerPower supplyunitSimple PAC-SE51CRAPAR-F27MEAPAR-21MAALOSSNAY Schedule timer

Strany 7 - U nique technology

Group remote controller PAC-SC30GRASystem exampleConnect to the centralized transmission lineR/C:Remote ControllerPower supply unitGroup remotecontrol

Strany 8 - T he world s first and

Backlight Color liquid crystalBacklight makes it easy to see and control units.One can identify whether a unit is ON or OFF from a distance.Control in

Strany 9 - E nergy Saving Technology

Energy Saving Control Enables Energy Saving Control with the use of our new PI controller. (Registration of “Energy Save” licence is required.)To pe

Strany 10 - Remote Controller

Up to 150 units can be controlled by AG-150A.**Expansion controller is required. Effective use of TG-2000A Multiple air conditioning charges in multip

Strany 11 - System Controller

BACnet interface(PAC-YG31CDA)Example of Basic System Configuration.LANAG-150ACentralmonitorBMSTG-2000A(Optional)Web Browser(Optional)BACnet inter

Strany 12 - Individual

Known the world over, the name Mitsubishi is a trusted household name associated with a variety of products and services. Founded in 1907, the company

Strany 13

Page38Remote ControllerBACnet® and M-NET adapter (BAC-HD150)Example of Basic System Configuration.CentralmonitorBMSBACnet/IPBAC-HD150BAC-HD150BACnet/

Strany 14 - Centralized

Ceiling cassette (4-way air flow)Ceiling concealedCeiling cassette (2-way air flow)Ceiling cassette (1-way air flow)Ceiling suspendedWall mountedFloor

Strany 15

SpecificationsNote: PLFY-P32VBM-E PLFY-P40VBM-E PLFY-P50VBM-E PLFY-P63VBM-E3.612,3004.013,6000.030.020.220.144.515,4005.017,1005.619,1006.321,5007.124

Strany 16

SpecificationsNote: ❇1 Cooling/Heating capacity indicates the maximum value at operation under the following condition.Cooling : Indoor 27˚C(81˚F)DB/1

Strany 17

SpecificationsNote: ❇1 Cooling/Heating capacity indicates the maximum value at operation under the following condition.Cooling : Indoor 27˚C(81˚F)DB/1

Strany 18

Power sourceCooling capacityHeating capacityPowerconsumptionCurrentExternal finishDimensionH ✕ W ✕ DNet weightHeat exchangerFanMotorAir filterRefriger

Strany 19 - (LMAP02)

SpecificationsNote: ❇1 Cooling/Heating capacity indicates the maximum value at operation under the following condition.Cooling : Indoor : 27˚CD.B./19˚

Strany 20 - and M-NET adapter

SpecificationsLiquid (R410A)(R22,R407C)Gas (R410A)(R22,R407C)Type ✕ QuantityAirflow rate(Low-Mid-High)External staticpressureTypeOutput CoolingHeating

Strany 21 - I ndoor unit

SpecificationsNote: ❇1 Cooling/heating capacity indicates the maximum value at operation under the following condition. Cooling Indoor : 2

Strany 22 - Specifications

SpecificationsNote: 1. The cooling and heating capacites are the maximum capacites that were obitained by operating in the above air conditions and wi

Strany 23

VRF systemOur answer to VRFMitsubishi Electric sets the boundaries of VRF technology with the City Multi range, which is available using R410A refrige

Strany 24

SpecificationsNote: ❇1 Cooling/Heating capacity indicates the maximum value at operation under the following condition.Cooling Indoor : 27˚C(80.6˚F)DB

Strany 25

SpecificationsNote: ❇1 Cooling/heating capacity indicates the maximum value at operation under the following condition.Cooling Indoor : 27˚C(81˚F)DB/1

Strany 26

SpecificationsNote: Cooling Indoor : 27˚C(81˚F)DB/19˚C(66˚F)WB, Outdoor : 35˚C(95˚F)DB Heating Indoor : 20˚C(68˚F)DB, Outdoor : 7˚C(45˚F)DB/6˚C(43˚

Strany 27

SpecificationsNote: ❇1 Cooling/Heating capacity indicates the maximum value at operation under the following condition.Cooling Indoor : 27˚C(81˚F)DB/1

Strany 28

SpecificationsNote: ❇1 Cooling/Heating capacity indicates the maximum value at operation under the following condition.Cooling Indoor : 27˚C(81˚F)DB/1

Strany 29 - PEFY-P VMH-E-F

Specifications44 49 57 64 73~220/230/240V 50Hz/60Hz2891,11052080.127/0.144/0.1610.060/0.068/0.0760.102/0.115/0.1270.048/0.054/0.0600.58/0.63/0.680.28

Strany 30

The secret to the unmatched comfort provided by Lossnay core is the cross-flow, plate-fin structure off the heat-exchange unit. A diaphragm made of a

Strany 31

In addition to the conventional Extra High, High, and Low modes, an Extra Low mode is added to provide a more dynamic range of air volume settings and

Strany 32

Appearance Model line upLGH-15~100RX5-ELGH-150 / 200RX5-EPage74LOSSNAYIn addition to the automatic damper open/close function, open/close control vi

Strany 33 - Floor standing exposed

Ventilation modeFan speedCurrent (A) Power consumption (W) Air volumeModelExternal static pressure Temperature exchange efficiency (%)Enthalpy exchang

Strany 34

I nverter Driven Compressor Technology - now up to 50HPUsing inverter driven technologysaves energy for several reasons:The compressor varies its s

Strany 35

ControlThe New Remote Controller PZ-60DR-E enable simple control settingCentralized Controller SystemLOSSNAY independentInterlocked with Air condition

Strany 36 - 16˚C (60.8˚F)

GUF - For the finest indoor qualityGUF = [ LOSSNAY ] + [ HEATING & COOLING ] RDH3 SERIESOUTDOOR AIR PROCESSING UNIT GUF typeGeneral Specificatio

Strany 37 - RX5 SERIES

O utdoor unitHeat Pump Series (Y)Heat Pump Series (S)Heat Pump Series - High COP (Y)Heat Pump Series - ZUBADAN (Y)Water cooled Heat Pump Series (WY)He

Strany 38 - Model line up

The two-pipe zoned system designed for Heat Pump OperationThe CITY MULTI S series (for small applications) and Y series (for large applications) make

Strany 39

Y series & R2 series Common Features inY (Heat Pump) series & R2 (Heat recovery) seriesCompact DesignThe downsized outdoor unit can be transpo

Strany 40 - Centralized Controller System

Bringing a year round comfort solutions to extreme climatesCITY MULTI ZUBADAN series combines the ultimate in application flexibility and powerful coo

Strany 41 - OA Processing

Maximum Stable OperationHeating up to250 min. straightReduced Defrosting timeBy utilizing our advanced Flash Injection Circuit, the system can not onl

Strany 42 - O utdoor unit

Water energy source system allows switchingbetween cooling and heating.The WY-Series has all the benefits of the Y-Series using water source condensin

Strany 43 - R2 (Heat Recovery) series

Heat Pump Series - High COP Y Series - High COP (8HP-12HP)PUHY-EP YHM-A(-BS)Page107Wide selection of outdoor units❇The PUHY-EP-YSHM-A and PUHY-HP-YSHM

Strany 44 - Common Features in

Heat Recovery Series - High COP R2 Series - High COP (8HP-12HP)PURY-EP YHM-A(-BS)Page123Wide selection of outdoor units❇The PURY-(E)P-YSHM-A series re

Strany 45

The difference between YHM-A and previous Mitsubishi Electric modelsTechnology is key when increased efficiency is demanded. The City Multi YHM-A rang

Strany 46 - (HP400 and HP500 models)

PUMY-P YHMB(-BS)OUTDOOR UNITS SeriesSpecificationsNote: ❇1 Nominal cooling conditionsIndoor 27˚CDB/19˚CWB (81˚FDB/66˚FWB), Outdoor 35˚CDB (95˚FDB)Pipe

Strany 47 - Water Cooled Series

PUHY-P YHM-A(-BS)OUTDOOR UNITY SeriesSpecificationsPower sourceCooling capacity (Nominal)Temp. range of coolingHeating capacity(Nominal)Temp. range of

Strany 48 - Heat Pump Series

PUHY-P YSHM-A(-BS)OUTDOOR UNITY SeriesSpecificationsNote: ❇1 Nominal cooling conditionsIndoor 27˚C (81˚F) DB/19˚C (66˚F) WB, Outdoor 35˚C (95˚F) DBPip

Strany 49 - Heat Recovery Series

PUHY-P YSHM-AOUTDOOR UNITY SeriesSpecificationsSet namePower sourceCooling capacity (Nominal)Temp. range of coolingHeating capacity(Nominal )Temp. ran

Strany 50

PUHY-P YSHM-A(-BS)OUTDOOR UNITY SeriesSpecificationsSet namePower sourceCooling capacity (Nominal)Temp. range of coolingHeating capacity(Nominal )Temp

Strany 51

PUHY-EP YSHM-A(-BS)OUTDOOR UNITY Series - High COPSpecificationsSet namePower sourceCooling capacity (Nominal)Temp. range of coolingHeating capacity(N

Strany 52

PUHY-EP YSHM-A(-BS)OUTDOOR UNITY Series - High COPSpecificationsSet namePower sourceCooling capacity (Nominal)Temp. range of coolingHeating capacity(N

Strany 53

PUHY-EP YSHM-A(-BS)OUTDOOR UNITY Series - High COPSpecificationsNote: ❇1 Nominal cooling conditionsIndoor 27˚C (81˚F) DB/19˚C (66˚F) WB, Outdoor 35˚C

Strany 54

PQHY-P YHM-AHEAT SOURCE UNITWY (Heat Pump) SeriesSpecificationsCapacityPower sourcePower inputCurrentCOPCompressorHeat exchangerCirculating waterRefri

Strany 55

PQHY-P YSHM-AHEAT SOURCE UNITWY (Heat Pump) SeriesSpecificationsCapacityPower sourcePower inputCurrentCOPRefrigerant piping diameterSet nameModelCompr

Strany 56

History of refrigerantR22, an HCFC-based refrigerant, has been a popular choice for most chillers. R22 has been targeted by the Montreal Protocol to b

Strany 57

PURY-P YHM-A(-BS)OUTDOOR UNITR2 SeriesSpecificationsPower sourceCooling capacity (Nominal)Temp. range of coolingHeating capacity(Nominal)Temp. range o

Strany 58

PURY-P YSHM-A(-BS)OUTDOOR UNITR2 SeriesSpecificationsSet namePower sourceCooling capacity (Nominal)Temp. range of coolingHeating capacity(Nominal)Temp

Strany 59

Note: ❇1 Nominal cooling conditionsIndoor 27˚C (81˚F) DB/19˚C (66˚F) WB, Outdoor 35˚C (95˚F) DBPipe length 7.5 m (24-9/16 ft), Level difference 0 m (0

Strany 60

PURY-EP YSHM-A(-BS)OUTDOOR UNITR2 Series - High COPSpecificationsNote: ❇1 Nominal cooling conditionsIndoor 27˚C (81˚F) DB/19˚C (66˚F) WB, Outdoor 35˚C

Strany 61

Set namePower sourceCooling capacity (Nominal)Temp. range of coolingHeating capacity(Nominal)Temp. range of heatingIndoor unitconnectableSound pressur

Strany 62

PQRY-P YSHM-AHEAT SOURCE UNITWR2 (Heat Recovery) SeriesSpecificationsCapacityPower sourcePower inputCurrentCOPRefrigerant piping diameterSet nameModel

Strany 63

Page130Outdoor UnitPQRY-P YSHM-AHEAT SOURCE UNITWR2 (Heat Recovery) SeriesSpecificationsCapacityPower sourcePower inputCurrentCOPRefrigerant piping di

Strany 64

O ptional partsPage131>>4-way cassette type (PLFY-VBM/VCM)>>2-way cassette type (PLFY-VLMD)>>Ceiling concealed type (PEFY-VMH)>&g

Strany 65

Maintenance equipmentMaintenance cycle [Note that maintenance cycle does not mean guarantee period.]The following tables are applicable when using equ

Strany 66 - WR2 (Heat Recovery) Series

CITY MULTIMEE08K108MITSUBISHI ELECTRIC MULTIPLE SPLIT TYPE AIR CONDITIONERS SeriesThe Air Conditioning & Refrigeration Systems Works ac

Strany 67 - Optional parts

Equipment roomOffice compartmentOfficeOffice Meeting room BC controllerOutdoor unitRefrigerant piping: 2-pipe typeMeeting roomCoolingCoolingCoolingHea

Strany 68 - OPTIONAL PARTS FOR CONTROL

How does the R2 /WR2 Heat Recovery Systemoperate on 2 Pipe’s?The secret of City Multi heat recoverysystems lies in theThe BC Controller houses a liqui

Strany 69

What is Water-Cooled?It is possible now to combine the features of VRF with a water circuit using City Multi WR2/WY. In this case the heat is rejected