Strany 1 - REMOTE I/O UNIT

CNCFCU6-DX561CONNECTION AND MAINTENANCE MANUALBNP-B2302*(ENG)REMOTE I/O UNIT

Strany 2 - Precautions for Safety

3. INSTALLATION 3.2 Noise Countermeasures I-4 3.2 Noise Countermeasures 3.2.1 Connection of FG (Frame Ground) The frame should basically be grou

Strany 3 - CAUTION

3. INSTALLATION 3.2 Noise Countermeasures I-5 3.2.2 Shield Clamping of Cables (1) Cables requiring ground connection with lead wire The FG wire

Strany 4 - I. CONNECTION MANUAL

3. INSTALLATION 3.2 Noise Countermeasures I-6 3.2.3 Connecting Spark Killers Connect a spark killer on the coil or contact in parallel for noise

Strany 5 - II. MAINTENANCE MANUAL

3. INSTALLATION 3.3 Installation I-7 3.3 Installation Each unit is installed in the sealed structure cabinet as a principle. When installing int

Strany 6 - I. CONNECTION MANUAL

3. INSTALLATION 3.4 Mounting Conditions I-8 3.4 Mounting Conditions (1) Parts, highly susceptible to dust, are mounted with a high density insi

Strany 7 - 1. OUTLINE

4. SYSTEM CONNECTION 4.1 General System Diagram I-9 4. SYSTEM CONNECTION 4.1 General System Diagram FGSV1CF10CF11R000MC1 MC1MC1CF11 CF10AUX2EMGB

Strany 8 - 2. CONFIGURATION

5. CONNECTION OF UNIT 5.1 Names of Each Part I-10 5. CONNECTION OF UNIT The methods for connecting to each unit and device are briefly explained

Strany 9 - Power specifications

5. CONNECTION OF UNIT 5.2 Unit Connection System Diagram I-11 5.2 Unit Connection System Diagram F010 cableCF10 RIO1↑01CS1 CS2↑CF10Remote I/O un

Strany 10 - 3.2 Noise Countermeasures

5. CONNECTION OF UNIT 5.3 Connection of Base I/O Unit I-12 5.3 Connection of Base I/O Unit The RIO1 connector is used for connection to the base

Strany 11 - CF34CF33

5. CONNECTION OF UNIT 5.4 Connection of RIO Unit I-13 5.4 Connection of RIO Unit The RIO2 connector is used to connect several remote I/O units.

Strany 12

Precautions for Safety Always read the specifications issued by the machine maker, this manual, related manuals and enclosed documents before s

Strany 13 - 3.3 Installation

5. CONNECTION OF UNIT 5.5 Connection of Power Supply I-14 5.5 Connection of Power Supply Supply the 24VDC power supply for the control circuit t

Strany 14 - 3.4 Mounting Conditions

5. CONNECTION OF UNIT 5.6 Connection of Encoder Speed Signal I-15 5.6 Connection of Encoder Speed Signal Encoder ENC1/2 (Note) Refer to follo

Strany 15 - 4. SYSTEM CONNECTION

5. CONNECTION OF UNIT 5.6 Connection of Encoder Speed Signal I-16 [Outline of connection] GNDPC∗PC1kΩ1kΩ100ΩENC1/2Spindleamplifier [Signal ass

Strany 16 - 5. CONNECTION OF UNIT

5. CONNECTION OF UNIT 5.7 Connection of Machine Input/Output Signal I-17 5.7 Connection of Machine Input/Output Signal Input Output Number of oc

Strany 17

5. CONNECTION OF UNIT 5.7 Connection of Machine Input/Output Signal I-18 [Signal assignment table] DO-LDI-LDI-RDO-LDI-LRemote I/O unitR-TMRI02 DC

Strany 18 - RIO1RIO2 DCIN

5. CONNECTION OF UNIT 5.7 Connection of Machine Input/Output Signal I-19 [Outline of input circuit] The digital signal input circuit includes the

Strany 19 - 5.4 Connection of RIO Unit

5. CONNECTION OF UNIT 5.7 Connection of Machine Input/Output Signal I-20 [Outline of output circuit] The digital signal output circuit is a source

Strany 20 - Stabilized power supply

APPENDIX 1 UNIT OUTLINE DRAWINGS AND INSTALLATION DIMENSIONS I-21APPENDIX 1 UNIT OUTLINE DRAWINGS AND INSTALLATION DIMENSIONS 0123456789ABCDEFST

Strany 21 - ENC pin No

APPENDIX 2 LIST OF CONNECTOR SETS I-22APPENDIX 2 LIST OF CONNECTOR SETS Connector case (3M) 10230-52F0-008 × 2 pcs. Strain relief

Strany 22

APPENDIX 3 CABLE MANUFACTURING DRAWINGS I-23APPENDIX 3 CABLE MANUFACTURING DRAWING As a rule, most F/R cables used with this product are

Strany 23

CAUTION 1. Items related to noise Always treat the shield cables indicated in this manual with grounding measures such as cable clamps. Sep

Strany 24 - X RX TX RX * TX RX TX RX *

APPENDIX 3 CABLE MANUFACTURING DRAWINGS I-24<Cable type name table> Appendix No. Cable type Application Max. length Standard cable lengt

Strany 25

APPENDIX 3 CABLE MANUFACTURING DRAWINGS Appendix 3.1 FCUA-R000 Cable Manufacturing Drawing I-25Appendix 3.1 FCUA-R000 Cable Manufacturing Drawin

Strany 26

APPENDIX 3 CABLE MANUFACTURING DRAWINGS Appendix 3.2 FCUA-R211 Cable Manufacturing Drawing I-26Appendix 3.2 FCUA-R211 Cable Manufacturing Drawin

Strany 27 - DIMENSIONS

APPENDIX 3 CABLE MANUFACTURING DRAWING Appendix 3.3 FCUA-R220 Cable Manufacturing Drawing I-27Appendix 3.3 FCUA-R220 Cable Manufacturing Drawing

Strany 28

APPENDIX 3 CABLE MANUFACTURING DRAWING Appendix 3.4 R300 Cable Manufacturing Drawing I-28Appendix 3.4 R300 Cable Manufacturing Drawing Applicat

Strany 29 - Soldering iron

APPENDIX 3 CABLE MANUFACTURING DRAWING Appendix 3.5 R301 Cable Manufacturing Drawing I-29Appendix 3.5 R301 Cable Manufacturing Drawing Applicat

Strany 30

APPENDIX 3 CABLE MANUFACTURING DRAWING Appendix 3.6 R-TM Manufacturing Drawing I-30Appendix 3.6 R-TM Manufacturing Drawing Application: Termin

Strany 31

APPENDIX 4 PRECAUTIONS FOR COMPLYING WITH UL/c-UL STANDARDS I-31APPENDIX 4 PRECAUTIONS FOR COMPLYING WITH UL/c-UL STANDARDS Observe the followi

Strany 32 - Note (3)

II. MAINTENANCE MANUAL

Strany 33 - Note (1)

1. EXPLANATION OF MODULE FUNCTIONS 1.1 FX2N-80BMT-NC Card II-1 1. EXPLANATION OF MODULE FUNCTIONS 1.1 FX2N-80BMT-NC Card [Block diagram] RI

Strany 34 - Note (1) (1)

FCU6-DX561 CONNECTION AND MAITENANCE MANUAL CONTENTS I. CONNECTION MANUAL 1. OUTLINE ...

Strany 35

1. EXPLANATION OF MODULE FUNCTIONS 1.1 FX2N-80BMT-NC Card II-2 [Connector layout diagram] RIO2U:DI-RL:DI-LU:ENC2L:ENC1SW2DCINDO-LSW1PROG.PORTRIO1

Strany 36 - D-3 AM P

2. FAULT DIAGNOSIS 2.1 List of Unit LEDs II-3 2. FAULT DIAGNOSIS 2.1 List of Unit LEDs DCINENC1ENC2ST No.POWERRUNCPU-ESTOPRUNRIO ERR1 ERR2DI-RDI-

Strany 37 - STANDARDS

2. FAULT DIAGNOSIS 2.2 Troubleshooting II-4 2.2 Troubleshooting 2.2.1 Confirmation of trouble state Confirm "when", "when doing w

Strany 38 - II. MAINTENANCE MANUAL

2. FAULT DIAGNOSIS 2.2 Troubleshooting II-5 2.2.2 When in trouble If the system does not operate as planned or if there is any trouble in the ope

Strany 39 - 1.1 FX2N-80BMT-NC Card

2. FAULT DIAGNOSIS 2.2 Troubleshooting II-6 (1) Problems related to the power supply The power does not turn ON. Cause Remedy The door interl

Strany 40

2. FAULT DIAGNOSIS 2.2 Troubleshooting II-7 (2) Problems related to remote I/O unit (FCU6-DX561) If any of the following problems occur, all point

Strany 41 - 2.1 List of Unit LEDs

2. FAULT DIAGNOSIS 2.2 Troubleshooting II-8 The operation display "RUN" LED does not turn ON. Cause Remedy The RUN/STOP switch is se

Strany 42 - 2.2 Troubleshooting

2. FAULT DIAGNOSIS 2.2 Troubleshooting II-9 2.2.3 Behavior of independent faults The EN954-1 Category 3 machine system must be designed so that th

Strany 43 - 2.2.2 When in trouble

3. DAILY MAINTENANCE AND PERIODIC INSPECTION AND MAINTENANCE 3.1 Maintenance Tools II-10 3. DAILY MAINTENANCE AND PERIODIC INSPECTION AND MAINTENA

Strany 44

3. DAILY MAINTENANCE AND PERIODIC INSPECTION AND MAINTENANCE 3.2 Replacement Methods II-11 3.2 Replacement Methods 3.2.1 Cable If the cable is re

Strany 45

II. MAINTENANCE MANUAL 1. EXPLANATION OF MODULE FUNCTIONS ... II-1 1.1 FX2N-80BMT-

Strany 46

3. DAILY MAINTENANCE AND PERIODIC INSPECTION AND MAINTENANCE 3.2 Replacement Methods II-12 b) For a flat cable type connector with claws, open the

Strany 47

3. DAILY MAINTENANCE AND PERIODIC INSPECTION AND MAINTENANCE 3.2 Replacement Methods II-13 3.2.2 Unit Usually, the unit is installed on the electr

Strany 48 - MAINTENANCE

Revision history Revision Date of revision Revision details ∗ 00/12/01 First edition issued

Strany 49 - 3.2 Replacement Methods

BNP-B2302* (ENG)REMOTE I/O UNIT・FCU6-DX561008-165(0110) MEESpecifications subject to change without notice.Printed in Japan on recycled paper.MITSUBIS

Strany 50 - (2) Pull

I. CONNECTION MANUAL

Strany 51 - 3.2.2 Unit

1. OUTLINE I-1 1. OUTLINE This manual explains the items required for installing and connecting the remote I/O unit (FCU6-DX561). The FCU6-DX561

Strany 52

2. CONFIGURATION 2.1 System Configuration I-2 2. CONFIGURATION 2.1 System Configuration 0OPENCBUS 2CBUS 1MITSU BISHIMDS-B -SVJ2Remote I/O uni

Strany 53 - REMOTE I/O UNIT・FCU6-DX561

3. INSTALLATION 3.1 General Specification I-3 3. INSTALLATION 3.1 General Specification Unit name Remote I/O unit Type name FCU6-DX561 Durin

Komentáře k této Příručce

Žádné komentáře