Mitsubishi MOTION CONTROLLERS Q173DCPU Manuál s instrukcemi Strana 61

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 252
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 60
2 - 32
2 SYSTEM CONFIGURATION
POINTS
(1) Be sure to turn OFF the Multiple CPU system's power supply before the rotary
switch setting change.
(2) It is recommended to shift to the mode operated by ROM after the programs
and parameters are fixed. The erasing of the programs and parameters can
be avoided even if the battery decrease. (The ROM writing cannot be
executed for the current position of the servo motor in the absolute position
system, home position and latch device. Back up them beforehand using
MT Developer2.)
Refer to Section 4.4 of the "Q173D(S)CPU/Q172D(S)CPU Motion controller
Programming Manual (COMMON)" for details of the ROM operation.
(c) Ethernet IP address display mode overview
7-segment LED Operation overview
Disconnect
Connect
(10Mbps)
Connect
(100Mbps)
Full duplex
Half duplex
IP address
(Note)
(ex. 192.168.3.39)
Subnet mask pattern
(Note)
(ex. 255.255.255.0)
Default router IP
address
(Note)
(ex. 192.168.3.1)
Link status
(Note): When the Ethernet parameters are not written in the Motion CPU, the addresses are
displayed as follows.
• IP address : 192.168.3.39
• Subnet mask pattern : 255.255.255.0
• Default router IP address : 192.168.3.1
Zobrazit stránku 60
1 2 ... 56 57 58 59 60 61 62 63 64 65 66 ... 251 252

Komentáře k této Příručce

Žádné komentáře